Installation and Maintenance Instructions
for Ashcroft A-Series Miniature
Watertight Pressure Switches
INTRODUCTION
The APS and APA pressure switch have NEMA 6, IP 67 Rated
316 stainless steel housing and process connections. The APS
has a factory fixed setpoint which cannot be changed in the field.
The APA is field adjustable and can easily be adjusted by follow-
ing the instructions in the diaphragm above.
ELECTRICAL CONNECTION
The APS and APA switch is available with many various electri-
cal connections. Refer to the figures on other side for wiring color
codes and identification of terminals. Depending on the configu-
ration, the Micro DIN mating connector may or may not be sup-
plied with the switch.
Only trained and skilled personnel are allowed to attach the
wires to the electrical terminals of the switch.
Cable couplers, glands and conduit connectors must have the
correct electrical approvals as required by local electrical codes.
The ground wire/connector is connected to the switch housing.
Fully insulated mating spade terminals must be used on all
spade terminal connections to prevent a shock hazard and
maintain compliance with approvals.
MICRO SWITCH RATINGS
CODE VAC RATING VDC RATING
H 5A @ 125/250VAC 5A @ 28Vdc resistive
3A @ 28Vdc inductive
P 3A @ 125VAC 2A @ 30Vdc resistive
G 0.1 A @ 125VAC 0.1A @ 30Vdc resistive
L 1A @125VAC 1A @ 28Vdc resistive
L 1A @125VAC 0.5A @ 28Vdcinductive
© 2011 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499, www.ashcroft.com
All sales subject to standard terms and conditions of sale.
I&M009-10045-10/11 (250-2966) Rev. 07/13
FIELD ADJUSTABLE
ADJUSTMENT
COVER
SLIDE COVER DOWN TO ACCESS
SETPOINT ADJUSTMENT SLIDE COVER
UP TO CLOSE AND SEAL ADJUSTMENT
ROTATE LEFT
<
TO INCREASE SETPOINT
ROTATE RIGHT
>
TO DECREASE SETPOINT
Ø .095 OR SMALLER TOOL
REQUIRED TO ROTATE NUT
FACTORY SET
L O O K F O R T H E S E MARKS ON OUR PRODUCTS
S I L 3 C A PABLE